January 26, 2015
This post will take a closer look at pharmaceutical storage tanks, specifically tank vents and common considerations that go in to selecting the right one for your application.
January 8, 2015
To begin, a Mill Test Report (MTR) in the world of sanitary process is a quality assurance document that documents the chemical and physical properties of the stainless steel (or other alloys) used in the fabrication of hygienic process components and equipment. MTRs go by a variety of names, including Certified Mill Test Report (CMTR), Mill Certification, or Metallurgical Test Report. When a heat (lot) of steel is generated at the mill, it is assayed. The results of that assay are recorded and an MTR is generated.
January 5, 2015
Due to recent customer demand, Holland is now offering pre-cut single use tubing made to our customer’s exact specifications. How can this benefit you? Let us explain.
December 5, 2014
Failure of the mechanical shaft seal is the most common cause of pump downtime. The shaft seal is exposed to a wide variety of conditions and it can be quite difficult to identify why a seal failed. This post will take a look at the most common costs of seal failure and readdress how we reduce the frequency of seal failure.
November 18, 2014
Previous posts to our blog have spent some time talking about BPE fittings and other parts of the ASME BPE Standards, but it occurred to us that a lot of people don’t know what the ASME BPE is. This post will go into some more detail.
November 6, 2014
Today’s post will take a look at sanitary perforated sheet and wedgewire strainers inserts and some of the advantages and disadvantages of each.
October 16, 2014
This post will take a look at a trick to identify your old C series, as well as a few other ways Holland can help support your aftermarket sanitary pump needs.
October 9, 2014
Today we’ll be take another look at the fill needle itself and cleaning considerations following manufacture- specifically, ultrasonic passivation.
September 4, 2014
A tremendous amount of this blog has focused on how we can optimize a process to get a product to the final filling stage, but little of the information available to consumers today focuses on the specific challenges that can occur during the final fill process. This post will highlight some common challenges during filling, needle tip geometries, and the problems they address.
August 26, 2014
Outside of efficiency, the low slip design of the Waukesha Universal series pump allows us to accomplish four useful things- it allows us to pump low viscosity fluids in low NIPA systems, it allows us to pump from vacuum vessels, self-prime, and meter fluids. This post will look at each of these four benefits and why they are important to system performance.
August 13, 2014
This post will focus on what a sanitary surface finish is and specifically the relationship between Ra, micron, and grit
August 7, 2014
One of the most common errors made when sizing an ECP pump, such as the Waukesha Universal 1 or Universal 2 series pump, is failing to take into consideration the range of product viscosities the pump will handle. This post will focus on that issue and what steps we can take to ensure adequate drive speed range is selected to handle a variety of products. To begin, a sanitary process system may require that the same pump handle both viscous and thin products. A simple example c
August 6, 2014
Today’s post will focus on another best in class product offered by Waukesha Cherry Burrell- the W60/80 line of seat valves and 5 specific benefits they offer over the competition.
July 31, 2014
This blog post is the first in a series that will try to give a concise overview of the properties relevant properties for single use tubing and connectors.
July 29, 2014
This post will focus on good sanitary pump piping practices and things you should keep in mind for your next sanitary PD pump install.
January 26, 2015
This post will take a closer look at pharmaceutical storage tanks, specifically tank vents and common considerations that go in to selecting the right one for your application.
January 8, 2015
To begin, a Mill Test Report (MTR) in the world of sanitary process is a quality assurance document that documents the chemical and physical properties of the stainless steel (or other alloys) used in the fabrication of hygienic process components and equipment. MTRs go by a variety of names, including Certified Mill Test Report (CMTR), Mill Certification, or Metallurgical Test Report. When a heat (lot) of steel is generated at the mill, it is assayed. The results of that assay are recorded and an MTR is generated.
January 5, 2015
Due to recent customer demand, Holland is now offering pre-cut single use tubing made to our customer’s exact specifications. How can this benefit you? Let us explain.
December 5, 2014
Failure of the mechanical shaft seal is the most common cause of pump downtime. The shaft seal is exposed to a wide variety of conditions and it can be quite difficult to identify why a seal failed. This post will take a look at the most common costs of seal failure and readdress how we reduce the frequency of seal failure.
November 18, 2014
Previous posts to our blog have spent some time talking about BPE fittings and other parts of the ASME BPE Standards, but it occurred to us that a lot of people don’t know what the ASME BPE is. This post will go into some more detail.
November 6, 2014
Today’s post will take a look at sanitary perforated sheet and wedgewire strainers inserts and some of the advantages and disadvantages of each.
October 16, 2014
This post will take a look at a trick to identify your old C series, as well as a few other ways Holland can help support your aftermarket sanitary pump needs.
October 9, 2014
Today we’ll be take another look at the fill needle itself and cleaning considerations following manufacture- specifically, ultrasonic passivation.
September 4, 2014
A tremendous amount of this blog has focused on how we can optimize a process to get a product to the final filling stage, but little of the information available to consumers today focuses on the specific challenges that can occur during the final fill process. This post will highlight some common challenges during filling, needle tip geometries, and the problems they address.
August 26, 2014
Outside of efficiency, the low slip design of the Waukesha Universal series pump allows us to accomplish four useful things- it allows us to pump low viscosity fluids in low NIPA systems, it allows us to pump from vacuum vessels, self-prime, and meter fluids. This post will look at each of these four benefits and why they are important to system performance.
August 13, 2014
This post will focus on what a sanitary surface finish is and specifically the relationship between Ra, micron, and grit
August 7, 2014
One of the most common errors made when sizing an ECP pump, such as the Waukesha Universal 1 or Universal 2 series pump, is failing to take into consideration the range of product viscosities the pump will handle. This post will focus on that issue and what steps we can take to ensure adequate drive speed range is selected to handle a variety of products. To begin, a sanitary process system may require that the same pump handle both viscous and thin products. A simple example c
August 6, 2014
Today’s post will focus on another best in class product offered by Waukesha Cherry Burrell- the W60/80 line of seat valves and 5 specific benefits they offer over the competition.
July 31, 2014
This blog post is the first in a series that will try to give a concise overview of the properties relevant properties for single use tubing and connectors.
July 29, 2014
This post will focus on good sanitary pump piping practices and things you should keep in mind for your next sanitary PD pump install.
What Our Customers Have to Say…
“Holland will put in the time and effort up front to fully comprehend complex processes, resulting in a system that meets, and frequently surpasses, expectations.”
Process Engineer – Pharmaceutical Contract Manufacturer
“Holland has been a reliable partner for many years. They have the ability to support our business thru their vast inventory of repair components, onsite field service and new replacement components. Holland has been proactive in providing recommendations for repair kits as well as carrying safety stock at their facility to support our specific needs.”
Operations Manager – Food Processing Facility
“Holland understands our need for not only quality products, but the detailed documentation and material traceability required in the pharmaceutical industry. We’ve used their Document Locator tool to help manage documentation for our production equipment. It’s been great to have a historical record of documentation covering our long-term relationship.”
Quality Manager – OEM of Single Use Biotech Equipment
““Holland Applied is a business partner that I find to be highly trustworthy, competent, and customer focused. We keep using them for our machining and fabrication needs because we know we can rely on them to provide high-quality goods on time and at competitive market prices.”
Head of Procurement – Injectable Drug Manufacturer
It’s Easy to Get Started
Need a Quote?
Tell us more about your project and challenges you’re facing, we’ll create a custom solution.
Need Expert Advice?